Water Resources Surface Water Software: Full Equations (FEQ) Model Web Resources
These notices are superseded by the release.txt distributed with the subsequent released versions of FEQ. User notices and bug reports (if any) for subsequent releases of FEQ and FEQUTL may also apply to this version.
This bug was introduced in version 10.0 with the feature to model the failure of a side-weir. It only affects models using a side-weir instruction, code=14, where an optional time-series table is given in NC(6) to define a time-dependent factor on the discharge. Fac is erroneously applied as a constant value of 1 instead of referencing the time-series table. This bug will be corrected in a future release.